FAQ
Frequently asked questions
Answers about AC4DC – sorted by the building blocks of the platform: from capturing data at machines, workstations and storage locations to the shared data foundation.
Getting started
General
What does AC4DC stand for?
AC4DC stands for Asset Connectivity for Data Context. The name describes what the platform does: connecting machines, equipment, workstations, material, processes and systems and giving their data context. This turns signals into information that MES, ERP, quality applications and AI can use directly.
Learn more in the glossary entry AC4DC.
What is industrial data management?
Industrial data management means connecting shop floor data consistently, classifying it semantically and making it available to all systems. AC4DC is built as an industrial data management platform: the pillars Connected Assets, Connected Workforce, Connected WIP and Monitoring & Operations build on a shared Platform Core with a semantic data model.
Learn more in the glossary entry IDM platform.
What are Quality4SF, Solve4SF and Inventory4SF?
Quality4SF, Solve4SF and Inventory4SF are packages of the AC4DC platform. Each package bundles platform capabilities into an offering for a specific need: Quality4SF for guided processes and the analysis of their results, Solve4SF for reporting and resolving disruptions quickly, and Inventory4SF for transparent inventory on the shop floor.
Which package fits your project is something we are happy to discuss in a conversation.
Foundation
Platform Core
How is AC4DC structured?
AC4DC consists of gateways and the Control Center. The gateways run close to the machine: they connect controllers, process signals into events and provide them to third-party systems. The Control Center is the central management environment for assets, gateways, interfaces and libraries – operated via the user interface or an API.
What does “Model once. Use everywhere.” mean?
Data structures, signal processing and messages are modelled once in libraries. Every further machine of the same type uses this model via a template – only the connection details need to be added. All downstream systems receive the same, consistently named events.
How does AC4DC scale to multiple plants?
Through the number of gateways – from a single plant to a group structure with many sites. Libraries and templates are maintained centrally and reused everywhere. Roles and permissions control access down to individual production sites.
How are changes rolled out in a controlled way?
Libraries are versioned and published. Each connection defines which version it uses. When a new version is created, AC4DC flags all affected configurations. Changes can be rolled out in a targeted way – and rolled back if necessary.
Is AC4DC ready for AI?
Yes. AI is only as good as the data it accesses. AC4DC delivers semantically structured, consistently named data with shop floor context – via open interfaces. Together with partners, we are already demonstrating this, for example with AI agents that answer questions about production in everyday language.
Do I need programming skills?
No, automation know-how is sufficient. Signal processing is based on the standard for PLC programming (IEC 61131-3). AC4DC includes predefined function blocks for basic operations, and a Structured Text editor is available for custom logic.
Does AC4DC run in the cloud or on premises?
Both are possible. AC4DC is containerized software for Kubernetes and runs on a mini industrial PC, an industrial PC, a server or in the cloud. Optionally, the gateway can run directly in the control cabinet next to the PLC.
What happens if the connection is lost?
If the connection to a third-party system is briefly interrupted, the gateway buffers the events and transmits them as soon as the connection is restored. How long and how many events are buffered is configurable.
How secure is AC4DC?
AC4DC reduces the attack surface with a lean architecture and few third-party components. Communication between the gateway and third-party systems is encrypted. Because the gateway can run right next to the controller, the unencrypted path is kept to a minimum. Roles and permissions control who can see and change what.
Capture · Machine
Connected Assets
Which machines can be connected?
Almost all common controller types – regardless of manufacturer and year of construction. Examples include Siemens S7, Heidenhain, controllers with an OPC UA server, Modbus TCP and Euromap 63; Stream Socket also connects any TCP byte stream. Which connection is possible in an individual case depends on the controller type and firmware. Further controllers on request.
What is the difference between a signal and an event?
A signal is the raw value from the controller, such as a bit or a counter value. AC4DC interprets these signals directly in the gateway and turns them into meaningful events – such as “machine in production”, “downtime” or “good part produced”. Downstream systems receive information instead of raw data.
Can AC4DC also write values to the machine?
Yes. AC4DC not only reads signals but can also write signals to controllers and receive and process commands from third-party systems such as MES or ERP. Reading and writing use the same connection.
Which systems can use the data?
Does the gateway have to be installed in the control cabinet?
No, that is an option. Thanks to its low hardware requirements, the gateway can run on an industrial micro PC right next to the PLC – keeping the unencrypted communication path to a minimum. It runs just as well on an industrial PC, a server or in the cloud.
How long does implementation take?
Installation takes less than two days: under one day for teams with Linux and Kubernetes know-how, plus one day with a guided setup by our experts. The first machine is connected in less than a day. Further machines of the same type are connected in under a minute using templates.
Capture · People
Connected Workforce
Which workflows can be mapped as guided processes?
Any workflow that an operator works through step by step – for example inspection plans, work plans, assembly plans and cleaning plans. You can define further plan types yourself. Each step can have its own fields, instructions and documents.
How is a plan started at the workstation?
Automatically or manually. Intervals based on quantity or time trigger the plan automatically for each workstation, and the operator is notified directly. Open tasks can also be started at any time from an overview – in the shop floor terminal or in the browser.
How much effort is it for operators to use?
Very little. Assistants guide operators through the plan step by step, with instructions and documents for each step. The interface is designed specifically for the shop floor and runs in the browser or directly in the shop floor terminal.
How do updated plans reach the workstation?
Plans are maintained centrally. Changes are available immediately at all assigned workstations – without printouts, outdated versions or redundant supplementary documents.
How do operators report malfunctions or material requirements?
Directly at the workstation: from the shop floor terminal, in the browser or via a link with a preselected report type. Templates ensure that the same information is always captured. Data from the shop floor terminal is transferred automatically.
Who is notified when an issue is reported?
Each report type is assigned to an expert group, which is notified automatically in the application or by email. If a report is not handled, defined escalation levels with time limits and additional recipients take effect.
Are reports available in multiple languages?
Yes. Report type names and the content of custom fields can be maintained in several languages – for international teams and plants.
Does AC4DC support audits according to ISO 9001 or IATF 16949?
Yes. Every step is documented digitally and completely – with result, time and reference to order and workstation. This provides a complete data basis for audits and compliance requirements. Certification itself remains the responsibility of your quality management.
Can this be integrated into our existing MES?
Yes. Plans and reports can be opened directly from the production workflow in the MES, for example from the shop floor terminal. Browser access and a REST API are available for the integration; data such as order or workstation can be adopted as production reference.
Capture · Material
Connected WIP
How does Connected WIP differ from warehouse management in ERP or WMS?
Connected WIP works at shop floor level: it makes inventory in intermediate storage and buffers between production steps visible – exactly where ERP and WMS systems usually have no insight. Connected WIP complements these systems and can be connected to them via an open interface.
Which inventory does Connected WIP make visible?
Work-in-progress inventory in production: material in buffers and intermediate storage, logically grouped by production step or process segment. For each storage location, you see the current occupancy as a number and as a chart.
How are load carriers registered and deregistered?
Directly at the storage location: with a handheld scanner, by manual entry, in the shop floor terminal or automatically via the REST API. This ensures that no goods are missed and reduces the effort for postings and corrections.
Which load carriers are supported?
Any you configure – for example Euro pallets, small load carriers (KLT), mesh boxes or special and transport trolleys. For each load carrier type, you define properties such as dimensions or weight and can add an image.
What happens if a load carrier is registered at the wrong storage location?
Storage locations can be configured to accept only certain load carrier types. If a load carrier that is not allowed is registered, the system displays a notice and marks the load carrier so that it can be found quickly.
Can the status of a load carrier be flagged?
Yes. Load carriers have attributes such as a release status, for example blocked, or a quality status, for example scrap. Load carriers can also be edited, reset and deregistered.
How do I keep track of dwell times?
Dwell time is monitored for each storage location. If it is exceeded, a notice appears directly at the storage location, and load carriers can be sorted by remaining dwell time in the overview. This shows you where material is waiting and where a closer analysis is worthwhile.
Can someone be notified automatically when limits are exceeded?
Yes. Notification rules automatically trigger a report for events such as a reached dwell time or inventory above or below a limit. It is sent directly to the responsible expert group – handling and escalation then work like any other report.
Can Connected WIP be integrated into our MES and ERP?
Yes. Via the REST API, third-party systems can execute all functions, such as creating storage locations or registering load carriers. This allows Connected WIP to be connected to your MES and ERP – load carriers can then be registered directly from the MES shop floor terminal, for example, without additional hardware.
Understand
Monitoring & Operations
What does Monitoring & Operations do?
Malfunctions, material requirements and requests from production are sent as reports directly to the responsible experts – for example in maintenance, warehouse or quality. There they are processed, escalated if necessary and evaluated. Calls and shouted requests become a traceable process with short response times.
How does a report reach the right person?
Each report type is assigned to one or more expert groups. When a report comes in, all members of these groups are notified at the same time – and only them. Every report reaches the right experts immediately without disturbing everyone else.
What happens if a report is not handled?
Escalation levels can be defined for each report type – a warning level and an alarm level, each with a time span from receipt of the report. When it expires, the level is triggered automatically, additional recipients are notified and the report is clearly highlighted in the overview.
How do experts process a report?
In a central overview, experts see new reports, reports assigned to them and all other reports. They set the status, assign processors, document progress with comments and attachments and close the report as soon as the problem is solved.
Through which channels are experts notified?
Directly in the application and by email. The email contains all relevant information and a link that opens the report immediately. Notifications are sent for new reports and when an escalation level is reached, and they can be adapted to the desired language.
Which key figures are available?
The evaluation shows reports per report type, processing time per report type, reports per status and the average response time. The data can be filtered and exported as CSV – as a basis for documentation and continuous improvement.
Can reports also be created automatically?
Yes. Third-party systems create reports via the API or a link with prefilled data. For example, warnings from Connected WIP – such as an exceeded dwell time or inventory below a limit – automatically create a report for the responsible expert group.
Can report types be adapted to our processes?
Yes. Report types are created centrally as templates – with custom fields and content, including extended data types such as links. Names and field contents can be maintained in several languages. Reports are always captured the same way across shifts and departments.
Which personal data is processed?
As little as possible. The application does not process any mandatory personal data; only the email addresses of the experts are required for notifications. Role-based user management controls access. When operated on premises, data sovereignty remains entirely within your company.